정보
X


Merck Chemicals

이상 less

TLC & HPTLC

Cellulose plates (TLC and HPTLC)

For analysis of polar substances

Merck:/topic/images/chrom/hptlc_blue_spectrum.jpgThe organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. Merck Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC cellulose layers are based on microcrystalline cellulose for standard separations, whereas HPTLC cellulose layers utilize high-purity rod-shaped microcrystalline cellulose resulting in a highly reduced diffusion of analytes for critical high-resolution separations.

Cellulose plates are available with or without fluorescent indicator. The fluorescent indicator used is a special fluorescent pigment that is stimulated to intense blue fluorescent emission at long-wave UV light of 366 nm and at short-wave UV light at 254 nm.

The special PEI cellulose is a polyethylenimine-modified cellulose, which acts as a strong basic anion exchanger. Due to these properties, it is mainly useful for analysis of substances with exchange-active, ionic groups such as amino acids, peptides and nucleotides or nucleosides.

 

Application of cellulose TLC and HPTLC
Typical applications of cellulose include the analysis of amino acids, carbohydrates, phosphates, nucleic acids and nucleic acid derivatives for:

  • Detection of significantly high increases of amino acids in clinical laboratories
  • 2-dimensional separations such as amino acid "fingerprints"
  • Metabolic studies

 

  10 × 10 cm 10 × 20 cm 20 × 20 cm
Cellulose 1.05632.0001 (glass) 1.05730.0001 (glass) 1.05716.0001 (glass)
1.05552.0001 (aluminum)
1.05577.0001 (plastic)
Cellulose F 1.05728.0001 (glass) 1.05716.0001 (glass)
1.05552.0001 (aluminum)
1.05577.0001 (plastic)
HPTLC cellulose 1.05787.0001 (glass) 1.05786.0001 (glass) 1.16092.0001 (aluminum)
HPTLC cellulose F 1.15035.0001 (glass) 1.15036.0001 (glass)
PEI cellulose F

1.05725.0001 (glass)

1.05579.0001 (plastic)

   

F: fluorescence indicator with excitation wavelength 254/366 nm
PEI cellulose plates should be stored at 0 - 4 °C to reduce deterioration. As plates become old they might take on a brown coloration and should be discarded.

 

 

TLC & HPTLC    
  TLC
    Aluminium Oxide
    Cellulose
    CN-, Diol-, NH2-modified Silica
    RP-modified Silica
    Silica (unmodified)
  HPTLC  
  PLC  
  Special Plates  


© Merck KGaA, Darmstadt, Germany, 2012


x

Welcome to Merck Millipore

 

유럽, 중동 및 아프리카 아시아 퍼시픽 북미, 중남미 South America

나라를 선택하십시오:

북미, 중남미

South America

유럽, 중동 및 아프리카

아시아 퍼시픽

All countries from A to Z

소속된 국가를 찾을 수 없다면 클릭하십시오 here.

 

x

Merck Chemicals Cart ()

You are entering the Millipore online shop. Both carts are maintained for you while you shop between sites. We recommend to complete your Merck order before visiting Millipore.com.

Go to Millipore Proceed to checkout


What kind of products are you looking for?

Millipore

Bio manufacturing and Life science.

머크 화학사업

High-quality industrial and laboratory chemicals.


Important message


머크 사이트에서는 바이오사이언스 제품을 다른 머크 제품과 함께 주문하실 수 없습니다. 우선 현재 진행중인 주문을 먼저 완료하시기 바랍니다.

현재 진행중인 주문을 취소하고 다음 단계로 진행하시겠습니까? 그렇다면, 쇼핑카트에 저장된 제품을 삭제하시기 바랍니다.